دوره 1، شماره 1 - ( July-Sep 1391 )                   جلد 1 شماره 1 صفحات 18-11 | برگشت به فهرست نسخه ها

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Salmani M, Ehrampoush M, Sheikhalishahi S, Dehvari M. Removing Copper from Contaminated Water Using Activated Carbon Sorbent by Continuous Flow. JCHR 2012; 1 (1) :11-18
URL: http://jhr.ssu.ac.ir/article-1-22-fa.html
Removing Copper from Contaminated Water Using Activated Carbon Sorbent by Continuous Flow. مجله تحقیقات سلامت. 1391; 1 (1) :11-18

URL: http://jhr.ssu.ac.ir/article-1-22-fa.html


چکیده:   (10186 مشاهده)
Introduction: A major concern of human being is accumulation and toxicity of heavy metals in their body. Copper is a heavy metal ion that in concentration of 2 mg/l can cause numerous complications. Different treatment methods have been proposed for removing metals from contaminated water by researchers. Among these methods, sorption seems a better method with high removal efficiency. In this study, conditions for removal of copper ions by activated carbon sorbent were studied with continuous flow. Materials & Methods: This was a laboratory – experimental study. A 20mg/l solution of copper ions was prepared and passed through a 5 × 10 cm column with average output rate of 1.85 ml/min. Output of column was sampled every 30 minutes and the remaining amount of copper ion in each sample was measured by flame atomic absorption. Results: The empty bed volume (EBV) was equal to 138 ml. The highest removal efficiency was 99.7 percent at 127 minutes. From equilibrium time, the removal efficiency was constant with time. The adsorption capacity of activated carbon was 0.25mg.g-1. The isotherm study indicated that the sorption data can be obeyed by both Langmuir and Freundlich isotherms (R2>0.95) but Langmuir model had higher agreement with this experimental data (R2= 0.988). Conclusion: The binding of ions to the sorbent in the adsorption process is extremely important. For this column 62.5 minutes after filling was appropriate, so the highest removal efficiency was obtained. Equilibrium time was dependent on the speed of influent through the column in the continuous flow. For selected column, the rate of 1.85 ml/min is a good performance.
واژه‌های کلیدی: Copper، Absorbent Pad، Charcoal، Water Pollution، Water Pollution Chemical
     
مروری: پژوهشي | موضوع مقاله: عمومى
دریافت: 1391/4/3 | پذیرش: 1394/3/12 | انتشار: 1394/3/12

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به مجله تحقیقات سلامت می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY 4.0 | Journal of Community Health Research

Designed & Developed by : Yektaweb